This page contains machine-translated content. For safety-relevant sections, the German original text is also shown and remains authoritative.

Experiment: Green steel; reduction of iron(III) oxide with hydrogen

ID: 208444  |  No.: 3108  |  Institut für Chemieinformation

Student experiment from Year 10 onwards

Category: Models and simulations, Metals and salts, Redox reaction

Note: Transferring to your DEGINTU account for risk assessment and its documentation is recommended!
📥 Log in to transfer to DEGINTU
Prerequisite: registration with the email address of your DEGINTU school account.
Permanent archiving (DOI)

No permanent DOI has been generated for this experiment yet.

Reaction equation

Zn + 2 HCl → ZnCl₂ + H₂ (exothermic)
Fe₂O₃ + 3 H₂ → 2 Fe + 3 H₂O (endothermic)
Acceleration: Zn + Cu²⁺ → Zn²⁺ + Cu
In the compressed gas cylinder variant, the zinc reactions do not take place.
Detection: Fe + 2 HCl → FeCl₂ + H₂
Comparison with the blast furnace: Fe₂O₃ + 3 CO → 2 Fe + 3 CO₂
Comparison with direct reduction using natural gas (Heinzerling, corrected in the erratum): Reformer: 3 CH₄ + 3 H₂O → 3 CO + 9 H₂; net reaction: 4 Fe₂O₃ + 3 CH₄ → 8 Fe + 6 H₂O + 3 CO₂

Procedure

⚠ Test procedure; not yet tested in the laboratory.

Preparation of the Kipp apparatus

  1. Place approximately 10 to 15 zinc granules through the side opening into the central reaction chamber.
  2. Measure out 30 mL of hydrochloric acid (10 %) in a measuring cylinder and add a few drops of copper(II) sulphate solution (1 mol/L). The copper accelerates the evolution of gas.
  3. Pour the acid through the upper opening until the granules are covered. Gas evolution begins.
  4. Insert the stopper with the two-way tap into the side opening and close the tap. The gas produced pushes the acid into the upper reservoir, bringing the reaction to a halt.

Preparing the pipette

  1. Push a small plug of steel wool, using the metal wire, until it is just short of the tapered end of the pipette.
  2. Using the microspatula, add a small amount of iron(III) oxide and, by tapping, spread it out into a thin layer approximately 5 cm long. The gas passage must remain clear.
  3. Connect the pipette to the two-way tap via the piece of tubing, clamp it horizontally and adjust the apparatus to the correct height. The tip of the pipette must point away from people and from the burner.

Procedure

  1. Open the tap: the acid flows back into the reaction chamber, whilst hydrogen flows through the pipette.
  2. Rinse for at least 1 min. Then collect the gas at the pipette tip in a small, inverted test tube and carry out the oxyhydrogen gas test away from the apparatus. Only continue working once it burns quietly.
  3. Light the burner and heat the iron oxide vigorously from below until it has turned completely black. Continue heating for a further 2 minutes or so (as a rough guide), as the black colour indicates only the initial stages of reduction. Keep the burner away from the cuvette and the pipette tip whilst doing so.
  4. Remove the burner and extinguish it. Leave the tap open until the pipette has cooled down (about 2 minutes), then close it.
  5. Hold a magnet against the outside of the pipette, near the reactant (previously, at an unheated point) and the product.
  6. Tap the cooled product through the wide end of the pipette into a test tube; the iron wool remains in the pipette, as it too would evolve gas and give a false positive for iron. Add about 2 mL of hydrochloric acid (10 per cent), keep away from flames, and watch for gas bubbles. For comparison, treat a spatula tip of unheated iron(III) oxide in the same way.

Variation: Hydrogen from a pressurised gas cylinder (teacher-led experiment only, in a fume cupboard)

Falling-back option if no Kipp’s apparatus is available: The pressurised hydrogen gas cylinder is connected directly to the pipette. ‘Directly’ means without a gas generator; a pressure regulator, fine-adjustment valve and non-return valve are still required. Zinc and copper(II) sulphate solution are not used; hydrochloric acid is only needed for detection. The pipette is prepared as described above.

  1. Set-up in the direction of flow: hydrogen pressure cylinder secured against tipping over, pressure regulator for hydrogen, fine-adjustment valve, non-return valve (flame arrestor), wash bottle containing a small amount of water to act as a bubble counter, pipette. The pipette and burner are located in the fume cupboard. Check all connections for leaks.
  2. Open the cylinder valve, set a small back pressure and use the fine-adjustment valve to regulate a weak gas flow (guideline: approximately 2 bubbles per second).
  3. Purge for at least 1 minute and carry out the oxyhydrogen test as described above. Only continue working once it burns quietly.
  4. Heat and cool under hydrogen; carry out the magnet test and hydrochloric acid detection as described above.
  5. Close the cylinder valve, relieve the pressure in the pipette, and close the pressure regulator and fine-adjustment valve. Remove the cylinder from the classroom after the experiment.

Observation

In the Kipp apparatus, gas bubbles rise from the zinc. When heated, the red powder initially turns black and becomes increasingly grey towards the end (Rosenberg et al. and Heinzerling describe the product as grey or steel-grey; not yet tested in the pipette), whilst water droplets condense on the glass wall behind the hot zone. The red reactant does not react to the magnet; the product follows suit and aligns itself with it. When treated with hydrochloric acid, the product produces gas bubbles, whereas the reference oxide does not.

Analysis

Hydrogen reduces iron(III) oxide via the intermediate stages of magnetite and wüstite to finely divided iron and is itself oxidised to water. The final step from wüstite to iron is the slowest. The reaction is endothermic and proceeds only with a constant supply of heat. In a blast furnace, carbon acts as the reducing agent, producing carbon dioxide; in reduction with hydrogen, water is the only by-product.

The model has its limitations. The product is not yet steel, but corresponds to the sponge iron produced by direct reduction; steel is only produced through smelting and alloying. The process is only ‘green’ if the hydrogen is produced by electrolysis using renewable electricity, which does not apply to hydrogen produced from zinc and hydrochloric acid. Bottled gas, too, is only green if it has been produced in this way; today, hydrogen is predominantly derived from natural gas. Magnetism alone does not prove the presence of iron, as magnetite (Fe₃O₄) is also black and magnetic. Only the evolution of gas when hydrochloric acid is added indicates the presence of metallic iron, as the oxides dissolve without producing gas. Heinzerling (see references) presents direct reduction using ammonia as a more cost-effective method. This, too, is only ‘green’ if the ammonia is derived from green hydrogen. The actual reducing agent here is also hydrogen, which is released from the ammonia (Ma et al., see References). VV #208490 contains a separate experimental design for this. As a transitional measure, direct reduction plants can operate using natural gas, which a reformer converts into synthesis gas consisting of carbon monoxide and hydrogen; this process also produces carbon dioxide.

Equipment & materials

Small-scale Kipp apparatus (Kipp cuvette; source cited as: Hedinger) with a small funnel, rubber stopper with a hole, suitable two-way tap, glass Pasteur pipette with a suitable length of tubing, lifting platform, stand with clamp, 50 mL graduated cylinder, dropper pipette, beaker, microspatula, metal wire for inserting the iron wool, gas burner, small test tube for the oxyhydrogen gas test, magnet, 2 test tubes in a stand, safety screen for demonstrations

Additionally for the pressurised gas cylinder variant: pressurised hydrogen cylinder with cylinder safety device, pressure regulator for hydrogen, fine-adjustment valve, non-return valve (flame arrester), wash bottle, hoses, fume cupboard; The tilting cuvette, stopper, tap, measuring cylinder, dropper pipette and beaker are not included.

For the test tasks (see ‘Miscellaneous’): hot-air blower, balance, analytical balance (0.1 mg), baking paper, quartz tube, empty gas-washing bottle, tray with ice water, second non-return valve (flame arrester).

Compiled by Claude on 4 November 2026 from the two sources; not yet tested. Hydrochloric acid 10 per cent, steel wool and the quantities (30 mL; estimated number of granules) are taken from the silent video; Schwab specifies sulphuric acid 1 mol/L and steel wool 000, but does not give any quantities. Additions compared with the sources: rinsing time, oxyhydrogen gas test, cooling under hydrogen (Schwab closes the tap before switching off the burner), note on magnetite, detection of hydrochloric acid, model limitations. Both sources are intended as pupil experiments; the client imposed the S9K restriction on 4 November 2026; testing is pending, and the compressed gas cylinder variant remains a teacher-led experiment. Heinzerling’s experiment uses ammonia and is incorporated into VV #208490 (full text available since 5 November 2026).

The compressed gas cylinder variant was added on request by Claude on 4 November 2026; it does not appear in either of the two sources, and the setup and bubble reference value have not been verified (published compressed gas setup: see addendum by Betten et al.). In this variant, zinc, copper(II) sulphate, zinc chloride and copper are omitted from the list of substances.

The ammonia variant was moved to its own VV #208490 on 4 November 2026 at the request of Claude.

Heat source (as specified by the client, on behalf of Claude, 4 November 2026): hot-air blower instead of a gas burner, where possible. The burner is still intended for iron reduction, as the blower is unlikely to be sufficient for this purpose. When testing with hydrogen, nevertheless try the blower at the highest setting first and verify the result with a test: if the temperature is too low, magnetite may form, which is also black and magnetic, meaning that the colour and magnetism merely simulate the presence of iron. A sample of the product in dilute hydrochloric acid only produces a distinct gas when iron is present. The blower nozzle is a source of ignition and remains hot after being switched off.

Erratum (on behalf of Claude, 4 November 2026): The two corrected equations have been aligned with the wording of the erratum and balanced. They relate to the natural gas route, not this experiment. The erratum text refers to iron(II) oxide, whilst the equation uses Fe₂O₃; the equation has been retained.

Addendum: References (on behalf of Claude, 4 November 2026). Chen et al., Hydrogen: Pure Fe₂O₃ in the form of a compressed pellet approximately 2 mm thick, heated continuously at a rate of 5 K/min in 10 L/h of pure hydrogen, reacts to 50 per cent at 457 °C, 90 per cent at 513 °C and 99 per cent at 530 °C (measurement data for Supplementary Fig. S3). The temperature therefore does not rule out the use of a hot-air blower from the outset, provided the powder reaches approximately 530 °C; this has not been measured. However, it takes a good 30 minutes and over 5 L of gas to go from 10 to 99 per cent conversion there, whilst the Kipp apparatus theoretically yields only about 1 L from 30 mL of hydrochloric acid at 10 per cent. The test task therefore remains; the blower in the source is a regulated laboratory instrument connected to a 0.6 mm capillary and does not constitute evidence for school-level equipment. At 700 °C (50 mg powder, 10 L/h), the mass loss is complete after around 2 minutes; the curve ends at approximately 83 per cent of the calculated conversion, which the essay does not explain. This gives rise to the guideline value of 2 minutes’ post-heating; the applicability to the pipette has not been tested. The rate-determining step is wüstite → iron, partly due to incomplete water removal; this supports the use of a thin layer and an unobstructed gas path. Nickel or nickel oxide lower the reduction temperature by around 100 K and halve the time, but are not adopted here: Nickel monoxide is Carc. 1A (H350i), nickel powder Carc. 2 (H351), STOT RE 1 (H372) and Skin Sens. 1 (H317).

Ma et al. state that porous iron is prone to highly exothermic re-oxidation; this supports cooling under hydrogen.

Test task: copper(II) oxide as an accelerator (on behalf of Claude, 4 November 2026; own, untested idea, not part of the procedure): Test whether adding some copper(II) oxide to iron(III) oxide accelerates the reduction or lowers the required temperature to such an extent that shorter heating times, less gas or the hot-air blower are sufficient. Chen et al. measure this effect for nickel; they only mention copper as a candidate following hydrogen adsorption and rule it out due to poor alloyability with iron, which is not an issue here. No effect has therefore been demonstrated. Suggestion: mix in approximately 10 mass per cent copper(II) oxide (guideline value) and compare with a blank sample without copper oxide, using the same heat source, time and gas volume, both with hydrochloric acid detection. In doing so, check whether copper interferes with the detection, as residues of copper(II) oxide dissolve in hydrochloric acid, and copper(II) ions react with iron. Copper(II) oxide is classified as Aquatic Acute 1 and Chronic 1 (H400, H410; M = 100); in DEGINTU, it is additionally classified as Acute Tox. 4; place residues in the container for waste containing heavy metals. It is included in the list of substances solely for this test. The copper(II) sulphate in the Kipps’ apparatus has nothing to do with this; it merely accelerates gas evolution at the zinc.

Addendum: Betten et al., Chemistry Lessons 186 (on behalf of Claude, 4 November 2026). Only the freely accessible opening section has been analysed; it breaks off at the reference. Figure 1 is not available, only the lead illustration on the page; whether it corresponds to the figure remains unclear. The article describes a teacher’s experiment as a demonstration for upper secondary level using hydrogen 5.0 from a pressurised gas cylinder: approximately 5 g of iron(III) oxide placed about 6 cm up in a quartz tube (20 × 2.6 cm) between quartz wool, flushing until the oxyhydrogen test is negative, heating for 4 to 6 minutes with a gas burner (with a diffuser if necessary), then cooling the product in a continuous stream of hydrogen for 6 to 10 minutes until lukewarm, whilst loosening it with a magnet. This supports the use of a pressurised gas cylinder as a teacher’s demonstration, purging with an oxyhydrogen test, the burner as a heat source, and cooling under hydrogen. The cooling time of approximately 2 minutes given in these instructions applies only to the small sample in the pipette; whether this is sufficient must be checked during testing. Variations not included here: a quartz tube and 5 g instead of a pipette and a micromount. According to the text and diagram, the non-return valve is situated at the gas outlet, where the escaping hydrogen burns off, and no safety device is shown between the bottle and the tube; here, it is situated before the pipette, and the gas flows weakly into the fume cupboard. The diagram shows a gas-scrubbing flask behind the tube in the water bath of the pneumatic trough, presumably as a cooling trap for the reaction water using the ice water (inferred from the diagram, not stated in the text). The role of calcium chloride and cotton wool remains unclear. None of this has been included in these operating instructions. A comparison with the full text is pending.

Test procedure for cooling trap (on behalf of Claude, 4 November 2026; based on the diagram in Betten et al., not part of the standard procedure, only the compressed gas cylinder variant): Install an empty gas-washing bottle in the ice water downstream of the pipette to collect the reaction water. Theoretically, 100 mg of iron(III) oxide yields only about 34 mg of water; it must be checked whether this becomes visible or remains in the pipette. The bubble counter, moistened with water, humidifies the gas before it reaches the pipette. For this experiment, it must therefore be placed behind the cold trap, and a blank test without iron(III) oxide must show that no water is produced in the absence of a reaction. With Kipp’s apparatus, the gas is already humidified, so the evidence is not conclusive. The wash bottle must not noticeably restrict the gas flow.

Test procedure: Burning off (as per Claude, 04/11/2026; not part of the standard procedure, only the compressed gas cylinder variant, in the fume cupboard): Up to this point, the gas flows weakly into the fume cupboard. It must be checked whether the excess hydrogen can be burned off at the outlet, as in the work by Betten et al. To do this, fit a second non-return valve (flame arrestor) at the outlet; only ignite it once the oxyhydrogen gas test has been passed, and do not take your eyes off the flame before turning off the gas; the hydrogen flame is barely visible. The flame constitutes an additional ignition source along the gas path and has not been tested in the small pipette. Rosenberg et al. also burn off the hydrogen at the tip, using copper wire in the glass tip and glass wool as a backflow preventer.

Addendum: Rosenberg et al., CHEMKON 32 (2025) 197–200 (on behalf of Claude, 5 November 2026). Demonstration using hydrogen in a vertically clamped quartz tube (20 cm, Ø 1.8 cm), filled in equal thirds with clay granules (Seramis), iron(III) oxide granules and clay granules; glass wool and copper wire in the glass tip to act as a flashback arrestor; negative oxyhydrogen test, ignite the hydrogen at the tip, heat to red-hot using a cartridge torch or soldering torch, then cool under hydrogen. This supports the flushing, the oxyhydrogen test, the use of a burner and cooling under hydrogen, as well as the grey final colour. If the glass pipette softens during testing, the published solution for the compressed gas cylinder variant is a quartz tube; both Betten et al. and Rosenberg et al. use one.

Not adopted: (1) Granules made from iron oxide and wallpaper paste. It keeps the gas passage open, but the authors themselves state that the acid test is not conclusive with this method; the hydrochloric acid test is an integral part of the procedure here. Presumably, the paste also carbonises in the red-hot state, and carbon can likewise reduce iron oxide (own assessment, untested). Figure 3 shows predominantly black pieces with grey and isolated red sections. (2) Ruling out magnetite using a magnetometer app. The fact that loose powder shows no measurable permanent magnetisation does not definitively rule out magnetite (own assessment, unconfirmed). (3) The term ‘blast furnace’; the text describes direct reduction in a shaft furnace. As an introduction to the lesson, the essay mentions the ‘Sendung mit der Maus’ programme on climate change and energy; for further exploration, a simulation game is suggested (Neff et al., see references).

Experimental task: mass balance (on behalf of Claude, 5 November 2026; according to Heinzerling, not part of the procedure): Weigh an empty pipette or quartz tube containing iron wool, then weigh it with iron oxide and, after the experiment, on the analytical balance (0.1 mg); remove any condensation beforehand. The ratio of initial weight to final weight is calculated as 1.43 for iron, 1.11 for wüstite and 1.03 for magnetite, and would distinguish between them without the use of acid. It must be checked whether the results are still unambiguous when using iron wool and moist gas from the Kipp apparatus; the iron wool may itself change mass within the gas stream.

Test procedure for water-glass granules (on behalf of Claude, 5 November 2026; according to Rossow/Flint, not part of the procedure, only for the quartz tube, not for the pipette): The paste recipe given by Rosenberg et al. is taken from Rossow/Flint, CHEMKON 13 (2006) 31–32. Water glass is listed there as the second binder: thicken iron(III) oxide powder with it, allow to dry to a thickness of about 3 mm on baking paper, and crush into pieces roughly the size of a pinhead. It does not carbonise, so the objection to the paste would not apply. A blank test should be carried out to check whether the granules remain gas-free without reduction with hydrochloric acid and whether the reduction proceeds completely within the grain (my own, untested expectation; the source did not investigate this using hydrogen). Sodium silicate is classified in DEGINTU as Skin Corr. 1B, Eye Dam. 1 and STOT SE 3; check the classification of the water glass solution used, and wear safety goggles and protective gloves when mixing. The teacher is responsible for preparing the solution.

Hazardous substances
Name Formula CAS no. H-statements P-statements Pictograms
Eisen, Pulver Fe 7439-89-6
H228 – Flammable solid.
German original: Entzündbarer Feststoff.
H252 – In large quantities, it is capable of self-heating; may catch fire.
German original: In großen Mengen selbsterhitzungsfähig; kann in Brand geraten.
P210 – Keep away from heat, hot surfaces, sparks, open flames and other sources of ignition. Do not smoke.
German original: Von Hitze, heißen Oberflächen, Funken, offenen Flammen und anderen Zündquellen fernhalten. Nicht rauchen.
P235 – Keep cool.
German original: Kühl halten.
P240 – Earth the container and the equipment to be filled.
German original: Behälter und zu befüllende Anlage erden.
P241 – Use explosion-proof electrical equipment / ventilation systems / lighting /...
German original: Explosionsgeschützte elektrische Betriebsmittel / Lüftungsanlagen / Beleuchtung /... verwenden.
P280 – Wear protective gloves / protective clothing / eye protection / face protection.
German original: Schutzhandschuhe / Schutzkleidung / Augenschutz / Gesichtsschutz tragen.
P403+P235 – Store in a cool, well-ventilated place.
German original: Kühl an einem gut belüfteten Ort aufbewahren.
GHS02
Eisen(III)-oxid Fe₂O₃ 1309-37-1
Kupfer, Pulver Cu 7440-50-8
H228 – Flammable solid.
German original: Entzündbarer Feststoff.
H410 – Very toxic to aquatic organisms, with long-term effects.
German original: Sehr giftig für Wasserorganismen mit langfristiger Wirkung.
P210 – Keep away from heat, hot surfaces, sparks, open flames and other sources of ignition. Do not smoke.
German original: Von Hitze, heißen Oberflächen, Funken, offenen Flammen und anderen Zündquellen fernhalten. Nicht rauchen.
P240 – Earth the container and the equipment to be filled.
German original: Behälter und zu befüllende Anlage erden.
P241 – Use explosion-proof electrical equipment / ventilation systems / lighting /...
German original: Explosionsgeschützte elektrische Betriebsmittel / Lüftungsanlagen / Beleuchtung /... verwenden.
P273 – Prevent release into the environment.
German original: Freisetzung in die Umwelt vermeiden.
P370+P378 – In the event of a fire: ... use to extinguish it.
German original: Bei Brand: ... zum Löschen verwenden.
GHS02, GHS09
Kupfer(II)-oxid CuO 1317-38-0
H410 – Very toxic to aquatic organisms, with long-term effects.
German original: Sehr giftig für Wasserorganismen mit langfristiger Wirkung.
P273 – Prevent release into the environment.
German original: Freisetzung in die Umwelt vermeiden.
GHS09
Natriumsilikat Na₂O · n SiO₂ 1344-09-8
H290 – May be corrosive to metals.
German original: Kann gegenüber Metallen korrosiv sein.
H314 – Causes severe chemical burns to the skin and serious eye damage.
German original: Verursacht schwere Verätzungen der Haut und schwere Augenschäden.
H335 – May irritate the respiratory tract.
German original: Kann die Atemwege reizen.
P234 – Store only in the original container.
German original: Nur im Originalbehälter aufbewahren.
P260 – Do not breathe in dust, smoke, gas, mist, vapour or aerosols.
German original: Staub / Rauch / Gas / Nebel / Dampf / Aerosol nicht einatmen.
P271 – Use only outdoors or in well-ventilated areas.
German original: Nur im Freien oder in gut belüfteten Räumen verwenden.
P280 – Wear protective gloves / protective clothing / eye protection / face protection.
German original: Schutzhandschuhe / Schutzkleidung / Augenschutz / Gesichtsschutz tragen.
P303+P361+P353 – IF IN CONTACT WITH THE SKIN (or hair): Remove all contaminated clothing immediately. Wash the skin with water or take a shower.
German original: BEI BERÜHRUNG MIT DER HAUT (oder dem Haar):Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen/duschen.
P305+P351+P338 – IF IN EYES: Rinse gently with water for several minutes. Remove any contact lenses if possible. Continue rinsing.
German original: BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Vorhandene Kontaktlinsennach Möglichkeit entfernen. Weiter spülen.
GHS05, GHS07
Salzsäure 10% HCl·aq
H290 – May be corrosive to metals.
German original: Kann gegenüber Metallen korrosiv sein.
H315 – Causes skin irritation.
German original: Verursacht Hautreizungen.
H319 – Causes serious eye irritation.
German original: Verursacht schwere Augenreizung.
H335 – May irritate the respiratory tract.
German original: Kann die Atemwege reizen.
P261 – Avoid inhaling dust, fumes, gas, mist, vapour or aerosols.
German original: Einatmen von Staub/Rauch/Gas/Nebel/Dampf/Aerosol vermeiden.
P280 – Wear protective gloves / protective clothing / eye protection / face protection.
German original: Schutzhandschuhe / Schutzkleidung / Augenschutz / Gesichtsschutz tragen.
P302+P352 – IF IT COMES INTO CONTACT WITH THE SKIN: Wash with plenty of water / ...
German original: BEI BERÜHRUNG MIT DER HAUT: Mit viel Wasser / ... waschen.
P304+P340 – IF INHALED: Move the person to fresh air and ensure they can breathe freely.
German original: BEI EINATMEN: Die Person an die frische Luft bringen und für ungehinderte Atmung sorgen.
P303+P361+P353 – IF IN CONTACT WITH THE SKIN (or hair): Remove all contaminated clothing immediately. Wash the skin with water or take a shower.
German original: BEI BERÜHRUNG MIT DER HAUT (oder dem Haar):Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen/duschen.
P305+P351+P338 – IF IN EYES: Rinse gently with water for several minutes. Remove any contact lenses if possible. Continue rinsing.
German original: BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Vorhandene Kontaktlinsennach Möglichkeit entfernen. Weiter spülen.
GHS05, GHS07
Wasserstoff H₂ 1333-74-0
H220 – Highly flammable gas.
German original: Extrem entzündbares Gas.
P210 – Keep away from heat, hot surfaces, sparks, open flames and other sources of ignition. Do not smoke.
German original: Von Hitze, heißen Oberflächen, Funken, offenen Flammen und anderen Zündquellen fernhalten. Nicht rauchen.
P377 – Fire caused by escaping gas: Do not extinguish until the leak can be safely rectified.
German original: Brand von ausströmendem Gas: Nicht löschen, bis Undichtigkeit gefahrlos beseitigt werden kann.
P381 – Remove all sources of ignition where it is safe to do so.
German original: Alle Zündquellen entfernen, wenn gefahrlos möglich.
P403 – Store in a well-ventilated place.
German original: An einem gut belüfteten Ort aufbewahren.
GHS02
Zinkchlorid ZnCl₂ 7646-85-7
H302 – Harmful if swallowed.
German original: Gesundheitsschädlich bei Verschlucken.
H314 – Causes severe chemical burns to the skin and serious eye damage.
German original: Verursacht schwere Verätzungen der Haut und schwere Augenschäden.
H410 – Very toxic to aquatic organisms, with long-term effects.
German original: Sehr giftig für Wasserorganismen mit langfristiger Wirkung.
P273 – Prevent release into the environment.
German original: Freisetzung in die Umwelt vermeiden.
P280 – Wear protective gloves / protective clothing / eye protection / face protection.
German original: Schutzhandschuhe / Schutzkleidung / Augenschutz / Gesichtsschutz tragen.
P308+P310 – IN CASE OF EXPOSURE or if affected: Call the POISON INFORMATION CENTRE or a doctor immediately.
German original: BEI Exposition oder falls betroffen: Sofort GIFTINFORMATIONSZENTRUM oder Arzt anrufen.
P301+P330+P331 – IF SWALLOWED: Rinse out the mouth. DO NOT induce vomiting.
German original: BEI VERSCHLUCKEN: Mund ausspülen. KEIN Erbrechen herbeiführen.
P305+P351+P338 – IF IN EYES: Rinse gently with water for several minutes. Remove any contact lenses if possible. Continue rinsing.
German original: BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Vorhandene Kontaktlinsennach Möglichkeit entfernen. Weiter spülen.
GHS05, GHS07, GHS09
Wasserstoff, Druckgas H₂ 1333-74-0
H220 – Highly flammable gas.
German original: Extrem entzündbares Gas.
H280 – Contains gas under pressure; may explode if heated.
German original: Enthält Gas unter Druck; kann bei Erwärmung explodieren.
P210 – Keep away from heat, hot surfaces, sparks, open flames and other sources of ignition. Do not smoke.
German original: Von Hitze, heißen Oberflächen, Funken, offenen Flammen und anderen Zündquellen fernhalten. Nicht rauchen.
P377 – Fire caused by escaping gas: Do not extinguish until the leak can be safely rectified.
German original: Brand von ausströmendem Gas: Nicht löschen, bis Undichtigkeit gefahrlos beseitigt werden kann.
P381 – Remove all sources of ignition where it is safe to do so.
German original: Alle Zündquellen entfernen, wenn gefahrlos möglich.
P403 – Store in a well-ventilated place.
German original: An einem gut belüfteten Ort aufbewahren.
GHS02, GHS04
Eisen, Wolle Fe 7439-89-6
Zink, Granalien Zn 7440-66-6
Eisen(II)-chlorid-4-Hydrat FeCl₂·4H₂O 13478-10-9
H302 – Harmful if swallowed.
German original: Gesundheitsschädlich bei Verschlucken.
H314 – Causes severe chemical burns to the skin and serious eye damage.
German original: Verursacht schwere Verätzungen der Haut und schwere Augenschäden.
P280 – Wear protective gloves / protective clothing / eye protection / face protection.
German original: Schutzhandschuhe / Schutzkleidung / Augenschutz / Gesichtsschutz tragen.
P310 – Call the POISON INFORMATION CENTRE / a doctor ... immediately.
German original: Sofort GIFTINFORMATIONSZENTRUM / Arzt ... anrufen.
P305+P351+P338 – IF IN EYES: Rinse gently with water for several minutes. Remove any contact lenses if possible. Continue rinsing.
German original: BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Vorhandene Kontaktlinsennach Möglichkeit entfernen. Weiter spülen.
GHS05, GHS07
Wasser, entionisiert H₂O 7732-18-5
Kupfer(II)-sulfat 1M CuSO₄·aq
H302 – Harmful if swallowed.
German original: Gesundheitsschädlich bei Verschlucken.
H318 – Causes serious eye damage.
German original: Verursacht schwere Augenschäden.
H411 – Toxic to aquatic organisms, with long-term effects.
German original: Giftig für Wasserorganismen, mit langfristiger Wirkung.
P273 – Prevent release into the environment.
German original: Freisetzung in die Umwelt vermeiden.
P280 – Wear protective gloves / protective clothing / eye protection / face protection.
German original: Schutzhandschuhe / Schutzkleidung / Augenschutz / Gesichtsschutz tragen.
P302+P352 – IF IT COMES INTO CONTACT WITH THE SKIN: Wash with plenty of water / ...
German original: BEI BERÜHRUNG MIT DER HAUT: Mit viel Wasser / ... waschen.
P305+P351+P338 – IF IN EYES: Rinse gently with water for several minutes. Remove any contact lenses if possible. Continue rinsing.
German original: BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Vorhandene Kontaktlinsennach Möglichkeit entfernen. Weiter spülen.
GHS05, GHS07, GHS09

H/P statements: machine translation, with the German original below (authoritative). Name, formula, CAS no. and pictograms are not translated.

Personal protective equipment
  • Safety goggles must be worn.
    German original
    Eine Gestellschutzbrille ist zu tragen.
  • Disposable nitrile gloves are used as splash protection.
    German original
    Als Spritzschutz dienen Nitril-Einmalhandschuhe.
Protective measures
Deduction for the compressed gas cylinder option. On behalf of Claude
German original
Abzug bei der Variante Druckgasflasche. i. A. Claude
⚠ Hazards
  • by inhalation
    German original
    durch Einatmen
  • through skin contact
    German original
    durch Hautkontakt
  • through eye contact
    German original
    durch Augenkontakt
  • Fire hazard
    German original
    Brandgefahr
  • Risk of explosion
    German original
    Explosionsgefahr
⚠ Further hazards and notes

Hazards (as per Claude, 4 November 2026): Hydrogen forms explosive mixtures with air. The iron wool is positioned on the outlet side. It only protects against ignition at the pipette tip, not against ignition in the hot zone towards the cuvette. Therefore, only heat after rinsing and carrying out an oxyhydrogen gas test; the source omits the test due to the small volume of gas. Freshly reduced, finely divided iron can self-ignite in air; therefore, allow it to cool under hydrogen and do not pour it out whilst hot. The glass pipette remains hot for a long time after heating. Reaction solutions containing chloride and copper are hazardous to water.

Variation using a pressurised gas cylinder (as per Claude, 4 November 2026): Unlike with the Kipp apparatus, the gas supply is not limited by the amount of zinc, and the cylinder is under high pressure (H220, H280). Therefore, this should only be carried out as a teacher’s demonstration in a fume cupboard, with a non-return valve and a low gas flow rate; escaping gas must not be allowed to accumulate in the room.

German original

Gefährdungen (i. A. Claude, 04.11.2026): Wasserstoff bildet mit Luft explosionsfähige Gemische. Die Eisenwolle sitzt auf der Auslassseite. Sie schützt nur gegen eine Zündung an der Pipettenspitze, nicht gegen eine Zündung an der heißen Zone in Richtung Küvette. Deshalb erst nach Spülen und Knallgasprobe heizen; die Quelle verzichtet wegen der kleinen Gasmenge auf die Probe. Frisch reduziertes, fein verteiltes Eisen kann an Luft selbst aufglühen; deshalb unter Wasserstoff abkühlen lassen und nicht heiß ausschütten. Die Glaspipette ist nach dem Erhitzen lange heiß. Chloridhaltige Reaktionslösung und Kupfer sind gewässergefährdend.

Variante Druckgasflasche (i. A. Claude, 04.11.2026): Der Gasvorrat ist nicht wie beim Kippschen Apparat durch die Zinkmenge begrenzt, und die Flasche steht unter hohem Druck (H220, H280). Deshalb nur als Lehrerversuch im Abzug, mit Rückschlagsicherung und schwachem Gasstrom; ausströmendes Gas darf sich nicht im Raum ansammeln.

⚠ Safety instructions
Wear safety goggles. During the demonstration, ensure the protective screen faces the pupils. Only heat the sample after rinsing and once the oxyhydrogen gas test has been passed. Keep the burner away from the cuvette and the pipette tip. Allow the pipette to cool under a stream of hydrogen. Use only pure zinc. Alternative using a pressurised gas cylinder: this experiment must only be carried out by the teacher in a fume cupboard; secure the cylinder, fit a non-return valve, and close the cylinder valve after the experiment. On behalf of Claude
German original
Schutzbrille tragen. Bei Vorführung Schutzscheibe zu den Schülerinnen und Schülern. Erst nach Spülen und bestandener Knallgasprobe heizen. Brenner von Küvette und Pipettenspitze fernhalten. Pipette unter Wasserstoff abkühlen lassen. Nur reines Zink verwenden. Variante Druckgasflasche: nur Lehrerversuch im Abzug, Flasche sichern, Rückschlagsicherung einbauen, Flaschenventil nach dem Versuch schließen. i. A. Claude
Substitution Substitution 1
The substitution of hazardous substances, as well as their forms of use and methods of application, has been assessed. This experiment is essential for teaching key learning content and can be carried out provided that the restrictions set out in the experiment instructions are observed and the protective measures specified therein are followed.
There are no known hazardous properties of the substances or other risks that would, in principle, preclude the experiment from being carried out by pupils or teachers. The list of substances in DGUV Information 213-098 at degintu.dguv.de has been taken into account.
Disposal

The apparatus, together with its contents, can be reused. Otherwise, dispose of the solution in the container for waste containing heavy metals; do not pour it down the drain. Once the product has cooled, moisten it; dispose of the pipette and its contents as glass waste. Place the test samples in the container for acidic inorganic waste. If using the pressurised gas cylinder method, no reaction solution is produced; the water from the wash bottle may be disposed of in the waste water.

Literature

M. Schwab: Reduction of iron oxide with hydrogen, https://www.fachreferent-chemie.de/wp-content/uploads/Reduktion-mit-Wasserstoff2.pdf.
Centre for Chemistry e. V. / School 3.0: Experiment: Reduction of iron oxide with hydrogen ‘Green steel vs. the conventional blast furnace process’, video, 26 September 2023, https://youtu.be/AlH3eIAEGaw (conducted by A. Ludewig, A. Knapp; based on Schwab, modified).
Further reading: P. Heinzerling: From research straight into the classroom: Green steel – direct reduction with ammonia, CHEMKON 31 (2024) 221–225, DOI 10.1002/ckon.202400004; Erratum: CHEMKON 32 (2025) 75, DOI 10.1002/ckon.202580242.
Max Planck Society: Green steel with ammonia, https://www.mpg.de/20212313/mit-ammoniak-zu-klimaneutralem-stahl.
Y. Ma et al.: Reducing Iron Oxide with Ammonia: A Sustainable Path to Green Steel, Adv. Sci. 10 (2023) 2300111, DOI 10.1002/advs.202300111.
X. Chen et al.: Solid–solid catalysis for sustainable alloy synthesis, Nat. Synth. 5 (2026) 1340–1348, DOI 10.1038/s44160-026-01086-5, with Supplementary Data 3.
S. Betten, K. Schürmann, D. Thiele, K. Sommer: Reduction of iron(III) oxide with hydrogen to iron, Chemistry Lessons No. 186 (2021), Friedrich Verlag, https://www.friedrich-verlag.de/friedrich-plus/sekundarstufe/chemie/chemische-reaktionen/reduktion-von-eiseniii-oxid-mit-wasserstoff-zu-eisen-10582 (only the freely accessible introduction was evaluated; page number missing; according to Rosenberg et al., experiment card).
Further reading: D. Rosenberg, T. Wagner, A. Hallmann: The blast furnace of the future – a pilot study on the blast furnace process using (green) hydrogen, CHEMKON 32 (2025) 197–200, DOI 10.1002/ckon.202400058.
M. Rossow, A. Flint: Oxygen from Oxi-purifiers – the blast furnace in a test tube, CHEMKON 13 (2006) 31–32.
Not consulted, cited in Rosenberg et al.: S. Neff, A. Engl, B. Risch: Climate-friendly steel production in the 21st century, Unterricht Chemie 186 (2021) 30–35.